Trust and transparency

Intesys infrastructure, in São Paulo data centers

FrontEngine runs on equipment and IP addresses that belong to Intesys. This page shows where that infrastructure is, who holds each certification and what the mail flow actually uses.

See the security measuresSee subprocessors

Our own network

  • Intesys IP address ranges

    Messages leave from addresses in the ranges 168.227.248.0/22 and 131.0.100.0/22, operated by Intesys. Delivery goes straight to the recipient's server, without passing through third-party sending services.

  • Our own autonomous system

    Intesys announces these ranges to the internet through its own autonomous system (ASN). Routing for the sending addresses is decided by us, not by a cloud provider.

  • Connectivity

    Both data centers are carrier neutral and have IX.br present. The Intesys network uses transit carriers and internet exchange points available in these buildings.

  • DDoS mitigation at the edge

    Attack traffic is filtered at the edge of the Intesys network, before it reaches the servers that receive your messages.

The two data centers

CharacteristicCirion SAO1Equinix SP3
LocationCotia, SPTamboré (Alphaville), Santana de Parnaíba, SP
OperatorCirion TechnologiesEquinix
Operator's Tier certificationUptime Institute Tier III (Design + Constructed)Uptime Institute Tier III (Design + Facility)
Power capacity20 MWAbout 13.3 MW
UPS2NN+1, block redundant
Diesel generators10, in 2N8, in N+1 with a swing unit
CoolingN+1N+1
Reachable carriersMore than 90More than 70
Internet exchange pointsIX.br on siteIX.br and Equinix Internet Exchange
Energy and building100% hydroelectric powerLEED Silver certified building
Use by FrontEngineAll of the mail flowNo mail flow today

Building data as published by the operators. Intesys occupies colocation space in both; the buildings, power and cooling are operated by Cirion and Equinix.

The certifications belong to the operators

Data-center certifications belong to whoever operates the facility. Intesys holds none of them.

  • Cirion SAO1: Uptime Institute Tier III for design and construction. Cirion also reports ISO 27001, ISO 22301, ISO 27701 and PCI-DSS certifications and SOC reports for its operation.
  • Equinix SP3: Tier III for design and facility, and LEED Silver for the building. Equinix also reports ISO 27001, ISO 22301 and PCI-DSS certifications and SOC 1 and SOC 2 reports for its São Paulo facilities.

Tier III means that power and cooling components can be serviced without shutting down the equipment installed in the building. These certifications cover the building and the data-center operation. They do not cover Intesys's systems or FrontEngine.

How FrontEngine uses this infrastructure

ComponentHow it runs today
SMTP and API submissionSeveral instances behind a load balancer, scaled automatically with demand
DatabaseThree instances with replication and a redundant connection pool
CacheThree instances with automatic failover of the primary
Event busThree nodes with replication
Analytics event storeReplicas with redundant coordination
Object storageFour nodes
Delivery to recipient serversOne process per IP pool, each a single instance

All of it in the Cirion data center in Cotia. Some components still run as a single instance: the delivery process of each pool, the queue scheduler and the on-disk queue volume. A failure in one of them delays delivery until it recovers.

Backups and a single site

The database has continuous backup of its transaction log and a full copy every day. Backups are encrypted and sent outside the data center. The provider that stores them is in the subprocessor list.

Restoring from these backups has been rehearsed, and so has the deliberate failure of data plane components.

The mail flow runs at a single site, Cirion in Cotia. Intesys is also present at Equinix SP3, but FrontEngine does not keep a second site there able to take over sending. An outage of the Cotia site interrupts the service until it recovers.

What we do not claim

  • Our own certification. Intesys holds no Tier, ISO, SOC or PCI certification. The ones on this page belong to Cirion and Equinix.
  • An availability percentage. We do not publish a number yet. It will be published in the SLA once it has been measured and approved.
  • Redundancy across sites. FrontEngine has no disaster recovery site for the mail flow.
  • Backup of messages. The backups described above cover the database, not the message archive.

Want to assess the infrastructure with your team?

We answer technical and security questionnaires about the network, the data centers and how FrontEngine is operated.

Talk to the teamRead the SLA